Pc1832 programming manual

Doing so may cause problems in the function of your alarm system. Even though your system comes factory defaulted; we suggest that you default the system just to make sure you have a clean slate to work with. To do this; follow the steps below:. To default the system you will enter into pc1832 programming manual mode by typing:.

Forever nerd and SaaS entrepreneur. Intrigued by software engineering, software as a business and aviation. I purchased the IT board and then decided I wanted to expand it a bit further to include more zones. I quickly realized I could use the IT board and some time to systematically determine the installer code but the time spent on that would be spent only because I had some concerns regarding reprogramming it. I decided to reprogram it myself and here are my notes for anyone attempting to program or even reprogram their own DSC alarm. The process is incredibly straight forward with only a few caveats.

Pc1832 programming manual

.

The motion is bypassed if a delay zone is triggered, giving you the ability to walk in front of the motion to get to a keypad. Below are additional sections you need to go pc1832 programming manual Press to change your installer code from the default setting of We will make the Front Door sensor delayed in zone 01, the Smoke Alarm will be standard 24 hour monitoring in zone 02, pc1832 programming manual, the Bedroom Window Sensor we will have Instant arming and disarming in zone

.

Table Of Contents. Table of Contents. Quick Links. This manual contains information on limitations regarding product use and function and information on the limitations as to liability. The entire manual should be carefully read. Previous Page. Next Page. Page 7: Additional Devices PC v1.

Pc1832 programming manual

.

Boisdale canary wharf dress code

This code is what you use to arm and disarm the system with. You will need to enter each zone edit label, edit label, etc. Type of Delay:. I have 24 zones on my system provided by the 8 default zones on the PC and the 16 additional zones from the two additional PC expanders. I purchased the IT board and then decided I wanted to expand it a bit further to include more zones. You select the letter you want by continuously pressing the same button until your desired letter or number appears. Therefore, I had to tell it not to consider the alarm in trouble mode if the telephone system was having issues in the Third System Option. This code is only used to get into programming and nothing else. Proceed to Checkout. You will want to enter programming by entering:. After entering the Installer Code we will now be in the Programming Section.

.

Press to change your installer code from the default setting of After each two-digit definition, the system will beep and automatically want the definition for the next zone. Step 2 Adding Zone Definitions Program Section We will begin adding our Zone Definitions and will use the above chart for reference and we will go straight down the list which begins with Zone Number Here was my table of zones and types:. Options that are on will be visible. Example: Zone 1- hardwired zone 2- hardwired zone 3-wireless zone 4- wireless You will enter into programming section and make sure 8 is on by pressing 8. By default, the keypad will display default zone definitions, ignore these numbers and enter you own. Type of Delay:. Time to factory reset the system. Then you can you the left and right arrows to move to the next location or simply press the next number which corresponds to your next character. The IT board was fun to mess with and was somewhat nostalgic. My alarm panel was in trouble mode until I told the system I will not be using the telephone system I am monitoring it via an online service.

0 thoughts on “Pc1832 programming manual

Leave a Reply

Your email address will not be published. Required fields are marked *